Приложение к Распоряжению от 01.12.2004 г № 1657-Р Перечень

Перечень коммуникационного, информационного оборудования


N P/n Наименование Кол.
1. Сервер Sun Fire E290 и дисковый массив SunStorEdge 3510
1 SR9-XKM038A-IP Cabinet, Sun Rack 900 with PDS Installed (For field product integration) 1
2 X6829A Power Cable, Outside No. Amer., Sun Rack PDS. Plug IEC309 IP44 16A, 3 Pin (Four 16A cables) 1
3 E29-4P32GB-1200 Sun Fire E2900 server. Includes 1 * CPU/Memory Board with 4 * 1.2GHz UltraSPARC s400 Processors (16MB cache each) and 32GB of DRAM (32 * 1GB DIMMs), 2 * 73GB 10Krpm hard disks, 1 * DVD-ROM, 2 * Gb ethernet ports, 1 * Ultra3 SCSI port, 4 * power supplies (2N redundancy), Interface Board-Standby System Controller (IB-SCC), and Solaris 9 (4/04) 1
4 SG-XPCI1FC-QF2 PCI Single FC 2Gb Host Bus Adapter (with SFS Drivers) 2
5 X322L Localized Power Cord Kit Continental Europe Sun Fire V1280 server only Contains 4 AC power cords 1
6 XTA3510R01A2V876 Sun StorEdge 3510 FC Array Rack Ready, 876GB (12 x 73GB 15K RPM disks) w/2 FC RAID controllers, 1GB cache, and 2 AC power supplies. Includes Sun StorEdge Configuration Service software 1
7 X312L Localized Power Cord Kit Continental Europe 4
8 X9732A 2M LC to LC FC Optical Cable 2
9 XTA-3000-2URK-19U Sun StorEdge(TM) 3000 2U universal rack, sliding rail kit. 2
10 NMK9S-00B-99Y9 Sun StorEdge Management Software Kit which includes Sun StorEdge Enterprise Storage Manager 2.0 Media & Documentation L10N; Sun Storage Automated Diagnostic Environment 2.3 Media, Documentation and RTU license; Sun SAN Foundation Software 4.3. No charge when purchased with Sun StorEdge Array 1
11 SOLZS-09HC9AYM Solaris 9 9/04 CD-ROM media kit. SPARC Platform Edition. Multilingual. No license, no hardcopy documentation 1
12 XTA3510R01A0V876 Sun StorEdge 3510 Rack Ready, 876GB (12 x 73GB 15K RPM disks), FC-JBOD, and 2 AC power supplies 1
2. Сервер Sun Fire E290 и дисковый массив SunStorEdge 3510
1 SR9-XKM038A-IP Cabinet, Sun Rack 900 with PDS Installed (For field product integration) 1
2 X6829A Power Cable, Outside No. Amer., Sun Rack PDS. Plug IEC309 IP44 16A, 3 Pin (Four 16A cables) 1
3 E29-4P32GB-1200 Sun Fire E2900 server. Includes 1 * CPU/Memory Board with 4 * 1.2GHz UltraSPARC s400 Processors (16MB cache each) and 32GB of DRAM (32 * 1GB DIMMs), 2 * 73GB 10Krpm hard disks, 1 * DVD-ROM, 2 * Gb ethernet ports, 1 * Ultra3 SCSI port, 4 * power supplies (2N redundancy), Interface Board-Standby System Controller (IB-SCC), and Solaris 9 (4/04) 1
4 SG-XPCI1FC-QF2 PCI Single FC 2Gb Host Bus Adapter (with SFS Drivers) 1
5 X322L Localized Power Cord Kit Continental Europe Sun Fire V1280 server only Contains 4 AC power cords 1
6 XTA3510R01A1V876 Sun StorEdge 3510 FC Array Rack Ready, 876GB (12 x 73GB 15K RPM disks) w/1 FC RAID controller, 1GB cache, and 2 AC power supplies. Includes Sun StorEdge Configuration Service software 1
7 X312L Localized Power Cord Kit Continental Europe 4
8 X9732A 2M LC to LC FC Optical Cable 1
9 XTA-3000-2URK-19U Sun StorEdge(TM) 3000 2U universal rack, sliding rail kit 2
10 NMK9S-00B-99Y9 Sun StorEdge Management Software Kit which includes Sun StorEdge Enterprise Storage Manager 2.0 Media & Documentation L10N; Sun Storage Automated Diagnostic Environment 2.3 Media, Documentation and RTU license; Sun SAN Foundation Software 4.3. No charge when purchased with Sun StorEdge Array 1
11 XTA3510R01A0V876 Sun StorEdge 3510 Rack Ready, 876GB (12 x 73GB 15K RPM disks), FC-JBOD, and 2 AC power supplies 1